Braidwood 2 — Nuclear Reactor Data & Live Status

Live reactor status, daily power data, outage history & performance charts, capacity factor & statistics, community ratings, technical specifications, NRC licensing data, photos, nearby jobs, satellite map, contact information, and per diem rates for Braidwood 2.

?
Composite Operational Excellence Score (0-100) — average percentile rank across 7 dimensions in three sub-scores: Reliability (capacity factor, forced outage days, B2B avg streak), Efficiency (fuel utilization, refuel duration), and Discipline (startup duration, scram count). 5-year window. Higher = more operationally excellent. Click to see the full breakdown.
87
Excellence
#5 of 93
Top Quartile
?
Current reactor power level from the most recent NRC daily report.
100%
Power
ONLINE
?
Days of continuous operation since the last outage ended. Ranked against all operating units.
125
Current Run
days
#69 of 95
Mid Quartile
?
Longest recorded period of continuous operation between outages.
549
Record Run
days
#63 of 95
Mid Quartile
?
Breaker-to-Breaker runs — continuous operation exceeding the cycle-adjusted threshold (468 days for this 18-month cycle unit) with no trips to 0% power.
10
B2B Runs
#9 of 87
Top Quartile
?
Lifetime capacity factor: average power level across all recorded days (100% = always at full power). Ranked against all NRC-tracked units.
94.7%
Capacity Factor
#4 of 95
Top Quartile
?
Net electricity actually generated over the most recent 12 months reported by the U.S. Energy Information Administration (Form EIA-923), summed across every unit at this plant. These are authoritative actuals, not an estimate.
19.57 TWh
Net Generation
EIA-923 · 12 mo to 2026-06 · plant total
?
Community rating score (Bayesian-adjusted). Based on 36 votes. Ranked against all rated facilities.
48.1
Rating
36 votes
#72 of 97
Mid Quartile
?
Total NRC-reported scram events (emergency reactor shutdowns). Ranked fleet-wide — fewer scrams = better rank.
0
Scrams
?
Years since commercial operation began. License remaining: 21.3 years.
37.9
Operating Age
years
21.3 yrs remaining

Reactor Status Timeline

Online NRC data, Mon to Fri ? Actual daily reactor status from NRC reports (Mon to Fri) and the current state. What is coming -- the utility's published Scheduled outage and NukeWorker's model Projection -- is part of a subscription. Colored by status. How far ahead you can see depends on your plan.
Oct2025NovDecJan2026FebMarAprMayJunJulAugSepOnline: Sep 8, 2025 to Mar 31, 2026Coastdown: Apr 1, 2026 to Apr 19, 2026Refueling Outage (A2R25): Apr 20, 2026 to May 6, 2026A2R25Power Ascension: May 7, 2026 to May 10, 2026Online: May 11, 2026 to Sep 8, 2026Today
OnlineCoastdownPower AscensionRefueling Outage
Full history & analysis →
?
Composite Operational Excellence Score for Braidwood 2 — average percentile rank across 7 publicly observable metrics in three sub-scores: Reliability (capacity factor, forced outage days, B2B avg streak), Efficiency (fuel utilization, refuel duration), and Discipline (startup duration, scram count). Toggle the time window (3yr / 5yr / Lifetime) to see how this unit's standing shifts. Each dimension percentile-ranked across the active US fleet. Sub-score = average of components. Composite = average of the three sub-scores.

NukeWorker's Operational Excellence Score 5-yr composite · ranks 5 of 93

NukeWorker scores Braidwood 2's operational excellence at 87 out of 100 over the past five years, ranking it 5 of 93 reactors in the active US fleet. The score blends reliability, efficiency, and operating discipline drawn from public performance data.
Time window
5-yr trend: 2021: 83/100 (#5/93)2022: 88/100 (#3/92)2023: 88/100 (#5/92)2024: 88/100 (#7/92)2025: 89/100 (#4/92)2026: 87/100 (#5/93) Stable vs 2025
Compare Braidwood 2 head-to-head with up to 3 other units. Compare now

Capacity Factor (365-Day)

?
100%
Current
94.3%
365-Day Avg
#56
of 94 plants
Min: 0% Max: 100% 23 days <80%
ELITE B2B CHAMPION 5+ RUNS CLEAN
4,813 days without a trip  ·  10 Career Runs  · 8 since last trip
Champion since Sep 3, 2015

Outage Duration Trend

?
Scheduled refueling outage durations over time. Green bars are below average, yellow near average, red above. Dashed line shows the plant's historical average. Shorter outages mean better execution.
Braidwood 2 has completed 19 scheduled refueling outages on record, averaging 20 days each. The most recent, in Apr 2026, ran 17 days.

Power History (12-Month)

?
Daily power output as a percentage of rated capacity over the past 365 days. Green segments indicate full power (90%+), yellow shows reduced output, and red indicates significant power reductions or shutdowns.
Over the past 12 months Braidwood 2 has run at an average of 94.3% of rated power. On the chart, green stretches are full-power running and dips toward zero mark reduced output or outages.

Outage Days by Year

?
Total days spent in outage each year, split by scheduled refueling (blue) and forced/unplanned (red). Lower totals indicate better reliability and outage execution. Hover for details.
Across its recorded history, Braidwood 2 has spent 389 days in scheduled refueling outages and 45 days in forced or unplanned outages. Taller bars mark the years with the most downtime.

Facility Statistics

?
Key performance and lifecycle metrics calculated from NRC operational data. Includes operating age, construction timeline, capacity factor, efficiency, generation totals, and reliability records.
Braidwood 2 has operated for about 37.9 years and averaged a 94.7% lifetime capacity factor, generating roughly 267.3 TWh of electricity. Its longest unbroken run reached 549 days.
Lifecycle & Tenure
Operating Age: 37.9 Yrs
Build Time: 12.8 Yrs
Lic. Remaining: 21.3 Yrs
Production & Power
Lifetime CF: 94.7%
Efficiency: 31.7%
Generated: 267.3 TWh
Reliability & Outages
Record Run: 549 Days
Refuelings: 19
Avg Startup: 3.7 Days

Location & Contact

?
Physical address, phone number, and website for this facility. Use the directions link to get driving directions via Google Maps.
Address:
35100 South Route 53
Braceville, IL 60407, USA
Get Directions
Phone: (815) 417-2000

Per Diem Rates FY 2026

?
Per diem covers lodging and meals & incidental expenses (M&IE) for government and contractor travel near this facility. Rates are from GSA for FY 2026.
$110
Lodging/Night
$68
M&IE/Day
$178
Total/Day
Standard Rate, IL

Unemployment Benefits IL

?
Maximum state unemployment insurance benefits for IL. Actual benefits depend on your earnings history and may be lower than the maximum. Data as of Jan 2026.
$859
Max Weekly
26
Max Weeks
$22,334
Max Total
7-day waiting period before benefits begin

Ownership & Construction

?
The utility or company that owns and operates the facility, the architect-engineer responsible for plant design, and the primary construction contractor. Click names to view all facilities by that entity on the map.
Owner/Operator: Constellation Energy
Architect Engineer: S&L
Constructor: CWE
CEG Constellation Energy Corporation NasdaqGS
$298.96 ▲ +13.91 (+4.88%)
Previous Close 285.05
Day's Range 284.04 – 299.73
52-Week Range 228.63 – 412.70
Volume 2,898,472
Delayed quote as of Sep 4, 2026 4:00 PM ET. Source: Yahoo Finance. Full quote on Yahoo Finance

Technical Specs

?
Reactor design specifications including type (PWR/BWR), containment design, nuclear steam supply system manufacturer, thermal and electrical power ratings, and current operational status.
Reactor Type: PWR
Containment: PWR-DRYAMB
NSS Supplier: WEST 4LP
Thermal Power: 3645 MWt
Net Capacity: 1154 MWe
Efficiency: 31.7%
Status: Operating

Licensing

?
NRC licensing history including docket number, license type and number, construction permit date, operating license issuance, commercial operation date, license renewal, and expiration date.
Docket #: 05000457
License #: NPF-77
License Type: OL-FP
Const. Permit: 1975-12-31
Operating Lic: 1988-05-20
Commercial Op: 1988-10-17
License Renewed: 2016-01-27
License Exp: 2047-12-18

Market & Region

?
EIA market and grid-region classifications: NERC reliability region, U.S. Census region, balancing authority responsible for grid operations, and whether the unit operates as a rate-regulated utility or a competitive merchant generator. Hover any value for the full name.
NERC Region: RFC — Reliability First Corporation
Census Region: ENC — East North Central
Balancing Authority: PJM — PJM Interconnection (ISO/RTO)
Market Structure: Merchant — Competitive generator selling into wholesale markets